Samenvatting
For the prevention and diagnosis of cardiovascular
diseases, the ability to measure cardiac performance is of great importance. A new type of sensor compatible for catheterization is proposed that can diagnose cardiovascular performance while being immune to Electromagnetic Interference (EMI), as well as compatible with Magnetic Resonance Imaging (MRI), with the ability to expand the number of sensors on a single catheter without additional wires. A prototype consisting of three cascaded pressure sensors on a single optical fiber has been fabricated,
allowing measurements of important local medical indicators,
such as Fractional Flow Reserve (FFR). The fabricated sensor is
able to measure blood pressure with a resolution of 3.6 mmHg at a rate of 2 kHz, with room for improvement. Although further work is needed in the miniaturization and integration of the sensor in a catheter, preliminary measurements show promising results.
diseases, the ability to measure cardiac performance is of great importance. A new type of sensor compatible for catheterization is proposed that can diagnose cardiovascular performance while being immune to Electromagnetic Interference (EMI), as well as compatible with Magnetic Resonance Imaging (MRI), with the ability to expand the number of sensors on a single catheter without additional wires. A prototype consisting of three cascaded pressure sensors on a single optical fiber has been fabricated,
allowing measurements of important local medical indicators,
such as Fractional Flow Reserve (FFR). The fabricated sensor is
able to measure blood pressure with a resolution of 3.6 mmHg at a rate of 2 kHz, with room for improvement. Although further work is needed in the miniaturization and integration of the sensor in a catheter, preliminary measurements show promising results.
| Originele taal | Engels |
|---|---|
| Aantal pagina's | 4 |
| Status | Gepubliceerd - mrt 2023 |
| Evenement | The Eighth International Conference on Advances in Sensors, Actuators, Metering and Sensing - Venice, Italië Duur: 24 apr 2023 → 28 apr 2023 https://www.iaria.org/conferences2023/ALLSENSORS23.html |
Congres
| Congres | The Eighth International Conference on Advances in Sensors, Actuators, Metering and Sensing |
|---|---|
| Verkorte titel | ALLSENSORS 2023 |
| Land/Regio | Italië |
| Stad | Venice |
| Periode | 24/04/23 → 28/04/23 |
| Internet adres |
Trefwoorden
- cardiovascular diseases
- blood pressure sensor
- MRI-compatible
- optical fiber
- catheter